top of page

BLAZE-prime 100 Watt Introductory Video

About Us
Allengers Global Healthcare Pvt. Ltd. is a healthcare equipment manufacturing company headquartered in Chandigarh, India. Incorporated in the year 2009, today we are leading manufacturers, suppliers and exporters of diagnostic, monitoring and surgical equipment like Holmium Lasers, EEG, EMG, PSG, TMT, ECG, and MPM in India.

 

100 Watt HOLMIUM LASER 

BLAZE-prime

  Ideal for:

  • Lithotripsy - RIRS, URS, PCNL ( Mini Perc and Micro Perc) 

  • BNI & Strictures 

  • HoLEP or BPH Treatment 

  • Tumor (Bladder, UUT) 

  • Soft tissue surgery.

  • Urethrotomy tumor excision.

Developed and manufactured by Allengers, one of India's largest Holmium Laser manufacturers.

Holmium Laser Machine - Allengers

ADVANTAGES OF HOLMIUM LASER

Holmium laser can break up all kinds of compositions of stones.

The dusting effect achieved from high-frequency holmium laser results in the ability of the sediments to pass through the urinary tract naturally.

The dusting effect achieved from high-frequency holmium laser results in the ability of the sediments to pass through the urinary tract naturally.

A higher-watt holmium laser can also be used for fine cutting of prostate and small tissues.

HOLMIUM LASER SYSTEM FOR LITHOTRIPSY AND PROSTATE SURGERY

HOLMIUM LASER SYSTEM FOR LITHOTRIPSY AND PROSTATE SURGERY

BEST IN CLASS MATERIAL

QUICK DELIVERY

LOW MAINTAIN-ANCE

PROMPT CUSTOMER SERVICE

ENQUIRE NOW

ADJUSTABLE VIEWING ANGLES

Tilt Movement - Holmium Laser Machine - Allengers

Tilt Movement

Sideways Swivel movement - Holmium Laser Machine - Allengers

Sideways Swivel movement

TURBO COOL WATER COOLING SYSTEM

Allengers BLAZE-prime has dual inverter compressor based cooling system for significant cooling even in long running time of machine operation. It enables machine to operate uninterrupted in all climate condition. The rapid cooling and maintained temperature to the optimal operating range of Holmium Laser machine allows improved laser beam parameter to best possible range. Thus, it reduces thermal lensing effect and improves life span of optical component inside laser machine and external fiber, hence reduces the running cost in long term due to good beam parameter.

TURBO COOL WATER COOLING SYSTEM - holmium laser machine - Allengers

IMPACT OF PULSE DURATION ON LASER LITHOTRIPSY

SHORT PULSE

The energy delivered by the single laser pulse occurs during a short period of time which is very effective for fragmentation of large stones and the ablation of soft tissues.

LONG PULSE

Long pulse with super imposed modulated pulse technique for pulse reshaping is designed to minimize retropulsion and eliminates the need of basket abstraction. This would help to reduce the total time of procedure.

BLAZE-prime IN BRIEF

  • Optical power upto 100 W.

  • Treatment of BPH, Bladder Tumor and HoLEP.

  • “Restoration” enables the surgeon to operate the patient on previously stored / saved settings, thus saving on crucial time needed to complete the procedure.

  • Variable pulse width.

  • Excellent hemostasis and coagulation.

  • Selectable energy and frequency range.

  • Selectable level for Aiming beam and Lasing sound.

  • Advanced compressor based turbo cooling system to enhance laser beam quality and efficiency of laser.

  • Advanced long pulse laser with super imposed modulated pulse to minimize retropulsion and enhance the

  • ablation rate.

  • Hands free Ready / Standby selection switch with dual foot pedal.

  • Low maintenance and minimal operating costs.

  • User friendly easy to operate touch screen interface.

FIBERS

The BLAZE-prime bare reusable fiber is supplied in sterile condition and is suitable for immediate first use without preconditioning. Bare fiber is indicated in general laser surgery application of different disciplines such as lithotripsy, incision, excision, vaporization and coagulation. Moreover the product can be used for fragmentation of stones and HoLEP application. BLAZE-prime reusable fiber has low OH for effective transmission of high power laser energy.

MULTI-FUNCTIONAL FOOT PEDAL / SWITCH

This comprises of Foot Paddle 1 or Foot Paddle 2 to allow easy switching between laser setting during procedure:-

Standby/Ready Foot Switch: This feature enables user/doctor to have full control of laser by switching between standby/ready mode without any assistance.
 

Foot Paddle 1 or Foot Paddle 2 can be suitably used for short pulse or long pulse independently or simultaneously for

different emission setting.

MULTI-FUNCTIONAL FOOT PEDAL / SWITCH

ENQUIRE NOW

OTHER BENEFITS OF HOLMIUM LASER

There is no risk or complication associated with the Holmium laser procedure.   
 

In the case of the RIRS/URS procedure, a flexible/Rigid endoscope or cystoscope is used to reach the stone in Kidney, Ureter or Bladder, through the urinary tract. Laser waves are then directed onto the stone to break it into small fragments or dusting.

As holmium laser enucleation of the prostate (HoLEP) has been introduced to relieve bladder outlet obstruction caused by benign prostatic hyperplasia (BPH). Compared with other techniques including the transurethral resection of the prostate (TURP) and simple open prostatectomy, HoLEP through holmium laser results in better cutting and less blood loss. With a holmium laser, HoLEP is an easy and safe technique for patients with a prior history of prostate problems and needing retreatment.
 
Thus the Holmium: YAG laser possesses both ablative and hemostatic properties and in preliminary clinical use, has demonstrated many potential urologic applications.

bottom of page